Find FRP Gas Scrubber, Frp Panels , Fiberglass Reinforced Panels on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > Frp Product > FRP Gas Scrubber > FRP Purification Tower Gas Scrubber Deep Bed Active Carbon Columns Dry Exhaust Gas Adsorption Tower

FRP Purification Tower Gas Scrubber Deep Bed Active Carbon Columns Dry Exhaust Gas Adsorption Tower

Basic Info

Model No.: ZLRC-ST2998

Product Description

Product Description

FRP Purification Tower Gas Scrubber Deep Bed Active Carbon Columns Dry Exhaust Gas Adsorption Tower
1.The classification:
The classification of fiber glass purification tower : Wet Exhaust Gas Cleaning and Dry Exhaust Gas Scrubber.Wet Exhaust Gas Cleaning divided into : packed tower, scrubber tower, desulfurizing tower,Swirl plate tower ,bubble cap tower,stripping tower,absorbing tower; Dry Exhaust Gas Scrubber divided into: activated carbon adsorption tower ,SDG dry acid waste gas adsorption tower . It apply to dispose harmful gas: sulfuric acid mist (H2SO4), hydrogen chloride (HCL) gas and hydrogen fluoride (HF) gas, chromium acid (CrO3), hydrogen cyanide gas (HCN), hydrogen sulfide (H2S), ammonia (NH3), nitrogen oxide (NOx), organic acid, benzene e,etc. The adopted way is different according to different waste gas.It is more better that using dry adsorption way for organic waste gas, and using wet purification or wet+dry adsorption way for Inorganic acid .
2.Introduction of two main type
A) Dry Exhaust Gas Scrubber:Dry scrubber use a catalyst to remove toxic components by chemisorption or adsorption to their surface. The required contact time is very short and does not depend on the inlet concentration. When most of the material has reacted, the cartridge with the catalyst has to be exchanged. This abatement method can be used for almost all processes used in the microelectronic industry. It does not require power, gases, or water for the gas cleaning. However, it requires maintenance. The catalyst has to exchanged regularly and the waste material has to be disposed. Adsorber material mixed with some color agent or indicator is used to indicate in a special window, when 90% of the catalyst has been used and the material needs to be exchanged. It is possible to install an automatic alarm based on an electronic color sensor.


B) Wet Exhaust Gas Cleaning:A wet scrubber is a simple method to clean exhaust air or exhaust gas and remove toxic or smelling compounds. In the flue gas scrubber, the gas gets in close contact with fine water drops in a co-current or counter current flow. This method is more effective when the water drop size gets smaller and the total surface between water or washing fluid and the gas gets larger. The water or washing fluid is recirculated normally in order to save water and reduce the amount of waste water.

3.Application:
Acid gas: sulfuric acid, HLC, nitric acid, HF etc.
Alkali gas: NAOH, KOH, NHS etc.
Organic gas: benzenes, alcohols, phenols.
We used different absorption solvent for dealing with different harmful gas.
4.Attention:
1. This purification tower should be installed on anti corrosion basis which is higher 100mm than ground. Pump with acid resistance should be on another anti corrosion basis.
2. This equipment should be installed indoor, in order to prevent cold weather from effecting on equipment and absorption solvent.
3. If there is no PH controlling system, PH of acid or alkali solvent should be checked regularly, and consistency should be adjusted at any time.
4. Spray-head and filling material should be checked regularly, in order to avoid plugging, any problems should be solved immediately.
5.Technical parameter:

Name
Air flow
Relative pump
Relative fan
Quantity of solvent
Weight of column body and total absorption solvent
Model
m3/h
Pump
Mot
Fan
Motor 
KG
 KG
kw
kw
1
2000-2600
40FSB-15L
2.2
4-72 5A
1.2
840
1280
2
5000-6000
40FSB-20L
3
4-72 5A
2.2
1820
2420
3
8000-10000
40FSB-20L
4
4-72 6A
4
3200
3900
4
14000-15000
65FSB-32L
5.5
4-72 6C
7.5
4200
5000
5
18000-20000
80FSB-20L
5.5
4-72 7C
11
5400
6400
6
30000-35000
100FSB-32L
5.5
4-72 8C
15
6600
7800
7
30000-35000
100FSB-32L
15
4-72 10C
18.5
7200
8200
8
40000-45000
100FSB-32L
15
4-72 10C
30
8100
12000
9
50000-60000
100FSB-32L
15
4-72 12C
37
10048
15000
Detailed Images
Feature

Gas Adsorption Tower

Application:
Acid gas: sulfuric acid, HLC, nitric acid, HF etc.
Alkali gas: NAOH, KOH, NHS etc.
Organic gas: benzenes, alcohols, phenols.
We used different absorption solvent for dealing with different harmful gas.

Gas Adsorption Tower

Attention:
1. This purification tower should be installed on anti corrosion basis which is higher 100mm than ground. Pump with acid resistance should be on another anti corrosion basis.
2. This equipment should be installed indoor, in order to prevent cold weather from effecting on equipment and absorption solvent.
3. If there is no PH controlling system, PH of acid or alkali solvent should be checked regularly, and consistency should be adjusted at any time.
4. Spray-head and filling material should be checked regularly, in order to avoid plugging, any problems should be solved immediately.

Packing & Delivery

FRP Purification Tower Gas Scrubber Deep Bed Active Carbon Columns Dry Exhaust Gas Adsorption Tower

Packing: As the customers' requirement.
Delivery Time: 10-20days after receive the deposit.

Related Products
Our Service
Certifications
FAQ

1.Q:What does your factory mainly produce ?
A:Our factory mainly produce frp machines and frp products.
2.Q:If your company can customzied by customers' requirements?
A:Yes,we can produce the machine with customized size.
3.Q:What is the payment method?
A:50% T/T in advance and the balance should be paid before delivery.
4.Q:What is the warranty?
A:Warranty is one year.
5.Q:If you can train customers how tu use the machine?
A:yes ,we can train in our factory or send our engineers to your factory.

Product Categories : Frp Product > FRP Gas Scrubber